Revolutionary Energy Optimization

The Ecod Smart Optimizer reduces energy consumption by maintaining the voltage at the optimal level, saving 6-14% on electricity bills.

Saves 6-14% on
Energy Bills

Cut down your electricity costs by 6-14%. The Ecod Smart Optimizer helps you maintain optimal voltage levels, ensuring efficient energy use without compromising performance.

  • Return on Investment in 1-3 Years
  • Reduce Energy Consumption
  • Gain Extended Equipment Lifespan
  • Protect Equipment
  • Reduce CO2 Emissions
  • Integrate Solar Panels with the Grid
  • Gain Increased Efficiency
ECOD Energy Optiizer

Benefits of ECOD

Energy Savings

Reduce energy bills by up to 14% with the Ecod Smart Optimizer’s optimized voltage control system.

Equipment Lifespan

Keep electrical devices running longer by maintaining stable voltage levels and reducing equipment stress.

Compact and Efficient

The Ecod Smart Optimizer features a smaller, lighter design that integrates seamlessly into your system.

Voltage Control

Optimizes voltage levels to minimize energy waste and deliver consistently high efficiency across your equipment.

Effortless Installation

Integrate the Ecod Smart Optimizer easily, without requiring special permits or complex installation procedures.

Maintenance-Free

No ongoing maintenance is required, providing a reliable, hassle-free solution for years of consistent performance.

ECOD Helps You to Tackle the Most Common Power Quality Issues

  • Reactive Power

    The phase angle between the current and voltage waveforms in an AC system. It is used to develop magnetic fields in motors and can cause a low power factor

  • Harmonics

    Multiples of the supply frequency, e.g., the fifth harmonic would be 250 Hz when the supply frequency is 50 Hz. They are caused by electronic loads such as variable speed drives and UPS systems.

  • Network Imbalance

    Differences in voltage between lines, caused by single-phase loads, phase-to-phase loads, and unbalanced three-phase loads, such as welding equipment.

  • Surges

    A sudden change in the sine wave that occurs in both voltage and current waveforms. They are caused by switching devices and the starting and stopping of high-power equipment.

  • Voltage Variations

    Include sags, swells, surges, and interruptions. Line voltage is higher or lower than nominal for a short period. They are caused by network faults, switching of capacitive loads, and excessive loads

  • Flicker

    Random or repetitive changes in voltage. Caused by mills, electric arc furnaces (EAF), welding equipment, and shredders

ECOD Operating Principle

Current Voltage Graph

The patented ECOD technology operates on a principle where an electronic controller regulates the direction of current in the coil of each transformer (one per phase), monitoring and balancing the network parameters. This is aimed at maintaining maximum efficiency with minimal power losses in the network.

Efficiency Graph

According to the diagram, we can clearly see that the efficiency of the air conditioner at a voltage of 210 to 220 V is close to 100%. This means that at this voltage, the air conditioner utilizes electrical energy optimally, achieving nearly 100% efficiency

Benefits Compared to Competitors

Feature Traditional Voltage Optimizers ECOD Voltage Optimizer
Technology Basic voltage regulation using transformers with specific capacities. Unique, patented technology regulating current in transformer windings.
Size and Weight Large and heavy due to transformer size. Three times smaller and lighter.
Energy Loss Higher losses due to larger size and weight. Reduces losses by more than six times, improving efficiency.
Energy Optimization Focuses on voltage optimization but is not very effective at minimizing losses. Optimizes energy (kWh), peak power (kW), and reactive power (kVAr).
Installation Limited flexibility due to large size. Compact design for easy integration in various environments.
Energy Savings Potential savings of around 4%, inconsistent, and often used internally. Consistent savings of 6-14% on selected loads.

Photovoltaics Efficiency

ECOD increases energy efficiency and eliminates shutdowns of photovoltaic systems, leading to enhanced energy production.

Date Average kW/day
19.01 -0.02
20.01 -28.11
21.01 -35.5
22.01 -3.88
23.01 -21.42
24.01 11.88
25.01 -16.59
26.01 -23.9
27.01 -23.2
28.01 -15.88
29.01 -27.67
30.01 -34.82
Date 19.01 20.01 21.01 22.01 23.01 24.01 25.01 26.01 27.01 28.01 29.01 30.01
Average kW/day -0.02 -28.11 -35.5 -3.88 -21.42 11.88 -16.59 -23.9 -23.2 -15.88 -27.67 -34.82

The minus sign indicates that the energy from the solar panels is sent to the grid.

Voltage and kW Charactrestics with and without ECOD

Voltage characteristics Without ECOD

Voltage Charactrestics Without ECOD

Voltage characteristics With ECOD

Voltage Charactrestics Wuth ECOD

kW characteristics Without ECOD

kW Charactrestics Without ECOD

kW characteristics With ECOD

kW Charactrestics Wuth ECOD

Web-Based Monitoring Platform for ECOD System

  • Live tracking of electricity consumption: Monitor your energy usage in real time, down to each device or equipment.
  • Detailed reports: Access historical data to understand energy trends and performance over time.
  • Cost-saving insights: See how much electricity you are saving with the ECOD system, including breakdowns by device or time period.
  • Remote control and management: Monitor and adjust the system settings remotely via the platform.
  • Compatibility with energy meters: The platform integrates with energy meters, providing accurate readings on energy consumption and voltage optimization.

The web-platform is available in the following languages: Polish, English, Chinese, French

ECOD System Monitoring Platform

Product Line ECOD

Model Nominal Current
per Phase (A)
Nominal
Capacity (KVA)
Dimensions
(H*D*W, mm)
Weight
(kg)
ECOD-ML-35-50 50 35 200*200*600 45
ECOD-ML-55-80 80 55 250*250*650 55
ECOD-ML-65-100 100 65 250*250*650 59
ECOD-ML-85-130 133 85 350*300*700 109
ECOD-ML-110-160 166 110 350*300*700 119
ECOD-ML-135-200 208 135 350*350*700 139
ECOD-ML-165-250 250 165 350*350*750 149
ECOD-ML-215-300 320 220 350*350*750 159
ECOD-ML-285-400 400 330 380*350*855 169